Consul air cooled stabilizers are rugged proven over 30 years. Air cooled stabilizers are available in natural and forced air cooled in a range from 3 – 500 KVA.

ADD TO WISHLITE

  • No potentiometer adjustments
  • All parameters can be modified using the keypad in the front panel
  • Small foot print & compact size
  • Set input voltage band
  • Set output voltage
  • Set output voltage sensitivity
  • Output over / under voltage cut-off
  • Input over voltage / under voltage cut-off
  • Over load cut-off.
  • Built-in Isolation Transformer
  • Trip time delay adjustments with variable setting
  • Opto isolated motor driven control
  • Manual and auto start facility
  • Common control card - any capacity
  • Output start and stop facility
  • Fully micro control function
  • Generator compatibility
  • Both outdoor and indoor models
  • True RMS sensing without control transformer for output and input

Capacity

3-350 KVA

Input Voltage Range*

A) Range 1 : 295 V-465 V B) Range 2 : 340 V-480 V C) Range 3 : 360 V-460 V D) Other ranges as per customer requirements

Output Voltage

380/400/415 V +1% Set

Input Frequency

47-53 Hz

Control Type

70 V per second

Correction Speed*

Digital-Micro controller based

Reset

Manual / Auto Reset with time delay and programmable

Protections

A) Electronic over & under voltage trip with time delay for input & output B) Electronic overload protection and short circuit protection upto 30 KVA through MCB and the Manual bypass is built in. Above 30 KVA MCB/MCCB is an optional. C) Surge Arrester/RF suppressor (OPTIONAL) D) Phase reversal protection and cut off E) Single phase prevention and cut off F) Neutral failure protection G) Frequency cut off protection H) Earth neutral voltage cut off protection

Metering Digital Type (Class 1 Accuracy With Full Scale ± 1)

A) Input phase to neutral B) Input phase to phase C) Output phase to neutral D) Output phase to phase E) Load Current in all the phases F) Frequency

Nature Of Cooling

Natural air cooled upto 150 KVA & Forced air cooled above 150 KVA

Effect Of Power Factor

Nil

Waveform Distortion

Nil

Annunciation Panel

Non Latching LED indications with dual colour for Overload Latching Conditions

Efficiency

> 98%

Cabinet Colour

Dark Grey

Provision Of Cabling

Input and Output terminations with provisions for fixing cable glands

Servo Motor Drive

Rugged AC step sychronous motor

Operating Temperature

0-45° C